Hardening Accelerating Water-reducing Admixture JF-6
JF-6 improves the early strength and later strength of concrete in the environment of alternating temperatures.
Category
Naphthalene series
Detail
Applications
JF-6 improves the early strength and later strength of concrete in the environment of alternating temperatures..
JF-6 is the major measures for speeding up the job scheduler and improving work efficiency.
JF-6 applies to the project of precast concrete, cast-in-place concrete, steam-cured concrete and early strength concrete.
Properties
Dosage: 1.5-2.5%, water-reducing rate: 10-15%.
JF-6 can save cement 10-15% and don’t decrease the strength, when it is circumstanced under the same slump constant.
JF-6 isn’t suitable for the steamed curing
Strength of JF-6 increases quickly.
JF-6 applies to concrete work under the condition of -5℃-30℃.
Uniformity
Item |
Results |
Item |
Results |
Appearance |
Isabelline powder |
pH Value |
7-9 |
Moisture content (%) |
5±1% |
Cement paste fluidity(mm) |
≥160 |
Fineness(0.315mm),< |
5% |
Chloride ion (%) |
≤0.6% |
Concrete performance with 2.0% dosage by binder mass
Test item |
Quality index |
Results |
|||
Hardening accelerating |
Standard |
Set retarding |
|||
Water reducing rate (%), ≥ |
8 |
8 |
8 |
14.4 |
|
Ratio of bleeding rate (%), ≤ |
95 |
100 |
100 |
24.3 |
|
Air content (%), ≤ |
4.0 |
4.0 |
5.5 |
3.0 |
|
Difference in setting time(min) |
Initial setting |
-90~+90 |
-90~+120 |
﹥+90 |
-67 |
Final setting |
— |
-23 |
|||
Ratio of compressive strength (%), ≥ |
1d |
135 |
— |
— |
320 |
3d |
130 |
115 |
— |
186 |
|
7d |
110 |
115 |
110 |
167 |
|
28d |
100 |
110 |
110 |
127 |
|
Ratio of shrinkage(%), ≤ |
28d |
135 |
107 |
Conclusion: the project is in line with early strength index of “High range water-reducing admixture” in GB8076-2008.
Packaging, transport and storage
Powder JF-6 is available in 25kg film-lined bags. Other special package can also be available according to prior consultation.
Special measures should be taken to ensure entire package. Keep waterproof during transportation. Dry and well ventilated warehouse is needed for storage. Quality guarantee of JF-6 is two year under normal conditions. If storage has surpassed the time, test must be done to confirm the validity.
Keyword
hardening
concrete